24 Chapter 3 Dialogic Analog Fax Boards
The following table lists I/O addresses and their switch settings for Dialogic board models whose I/
O addresses are set using three switches on the SW1 unit on the board.
Setting the board identifier
Each installed Dialogic CPi/200 PCI and CPi/400 PCI fax board must be assigned a unique board
identifier so the software can match the telephone numbers to the channels that reside on each
board. The unique board identifier is set using a rotary switch on the board.
To adjust the rotary switch, insert a small flat-head screwdriver in the arrow slot in the center of the
rotary switch. There are 16 available switch settings (from 0 to F hex). The arrow in the center of the
switch points to the current switch setting. Set each installed board to a unique switch setting.
Dialogic recommends setting the rotary switch before the board is installed. If you need to change
the board identifier after the board is installed, you must reboot the computer for the change to take
effect.
Installing Dialogic analog fax boards
Note For information on installing Dialogic CPD/220 fax boards, see Installing CPD/220 boards on
page 25
Fax boards can be installed in the RightFax server or in a separate computer called a remote
BoardServer. For information on using remote BoardServers, refer to the RightFax Administrators
Guide.
After all of your Dialogic fax boards are configured to use unique I/O addresses, you are ready to
install them. Always turn your computer off before inserting or removing any board, and take all
necessary precautions to prevent static discharge when handling any fax board. Dialogic CP, CPi,
and CPi/100 boards can be installed into either an 8-bit or 16-bit slot. All other Dialogic CP series
boards must be installed in a 16-bit slot.
After the fax boards have been installed, refer to your Dialogic documentation for instructions on
connecting the phone cables.
Table 3C SW1 Unit I/O Address Switch Settings
Channel A I/O
address
Channel B I/O
address
Channel C I/O
address
Channel D I/O
address
Switch
1
Switch
2
Switch
3
350 360 370 250 Off Off Off
260 270 150 160 On Off Off
100 104 108 10C Off On Off
110 114 118 11C On On Off
280 284 288 28C Off Off On
290 294 298 29C On Off On
120 124 128 12C Off On On
130 134 138 13C On On On