DSI Signaling Server SGW Mode User Manual Issue 5
Output Format
Uninhibiting C7LINK 23
Uninhibiting C7LINK 31
EXECUTED
6.9.5 MNRSI – Maintenance Restart System Initiate
Synopsis
This command restarts the entire system. All current logon sessions are terminated.
If a software update disk is present on a CD or USB, then the software update procedure commences.
If no software update disk is present, but a CD or USB containing a configuration dump is present, this
configuration is loaded into memory and the system restarts.
In all other cases, no change to the system configuration occurs and the state of all links is automatically
restored.
If RESET is set to Y, all configuration data is removed.
If SYSTYPE is set, the systems operating mode changes after restart. Possible operation modes are:
DSC – Digital Signaling Conveter
SGW – SIGTRAN Signaling Gateway
SIU – Signaling Interface Unit
Syntax
MNRSI:[RESTART=,][RESET=Y,][SYSTYPE=,];
Prerequisites
SYSTYPE can only be set to system types that have been licensed for the unit. See the CNSYP command.
Attributes
PROMPT
Examples
MNRSI;
MNRSI:RESET=Y;
MNRSI:SYSTYPE=SGW;
MNRSI:RESTART=SOFT;