Dialogic DSI SS7MD Manual do Utilizador Página 152

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 176
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 151
152
Chapter 8 Alarm Fault Code Listing
Major
(MJR)
66 NIF event ind
Diagnostic event relating to the Nodal
Interworking Function. Persistent events of
this type should be reported to your support
representative.
NONE 4
Major
(MJR)
67 NIF err ind
Diagnostic event relating to the Network
Interface Function. Persistent events of this
type should be reported to your support
representative.
NONE 4
Major
(MJR)
68 SNRT unavail Reserved SIG NC 4 0
Major
(MJR)
69 C7RT unavail One or more SS7 routes are unavailable SIG NC 40
Major
(MJR)
70 RAS unavail
One or more SIGTRAN Application Servers are
unavailable
SIG NC 4 0
Major
(MJR)
71 RAS under res
One or more SIGTRAN Application Servers are
available but have insufficient number of ASP
(load sharing mode only)
SIG NC 40
Major
(MJR)
73 M2PA event ind
Diagnostic event relating to the M2PA protocol
layer. Persistent events of this type should be
reported to your support representative.
NONE 4
Major
(MJR)
74 M2PA err ind
Diagnostic event relating to the M2PA protocol
layer. Persistent events of this type should be
reported to your support representative.
NONE 4
Major
(MJR)
81
Hard Disk
Drive Failure
A RAID 1 hard disk drive is unavailable or out
of synchronisation with the other disk of the
RAID array
SYS drive ID
Minor
(MRN)
16 Alarm Test 1
This event indicates that the user has invoked
the alarm test for alarm class 1 using the
ALTEI command.
SYS 0 5 0
Minor
(MRN)
19 System Restart
This event indicates the time at which a
system restart occurred.
SYS 0 5 0
Minor
(MRN)
34
New sync
source
The Signaling Gateway has selected a new
PCM as the clock synchronization source.
PCM PCM 5
Minor
(MRN)
79 Default alarm
The system has detected a low priority low
level alarm condition. The user should contact
their support contact for further information.
SYS 5
Table 10. Alarm Fault Codes (Continued)
Severity
(LED)
CODE Name Event Description CATEGORY ID Class
DIAG
† The “Class” column provides the initial default setting of the alarm class for each fault code. The alarm class for any particular alarm code
is configurable using the ALCLS command and can be viewed using the ALCLP command. Changing the alarm class for an event type changes
the Severity indicated by the LEDs and/or relays.