DSI Signaling Server SGW Mode User Manual Issue 5
Chapter 5: Parameter Definitions
5.1 Parameter Table
Table 3 lists parameters and details the possible values.
All numeric parameters are entered and output in decimal notation.
<text character> is either <lower case letter>, <upper case letter>, <digit>, $, or -. The use of quotation
marks to delimit text strings is not required.
Table 3. Parameter Definitions
Name Description Range Notes
ALP
Sequential reference number of an entry
in the Alarm Log
1 to 9999
AUTH
V3 SNMP Authentication encryption
protocol - used to ensure that V3 SNMP
requests have not be modified during
transit.
Set to SHA or MD5
AUTHPASS
SNMP V3 User account Authentication
password.
8 to 12
Must be set if the AUTH
parameter is set.
BCIC
The circuit identification code of an SS7
circuit that is the base CIC of a CIC
Range
0 to 4095
BPOS
Board position number (for signaling
boards)
1 to 3
BRDTYPE
Dialogic
®
DSI Network Interface Board
type descriptor, in the format:
xxxxxx-y-z
where:
xxxxxx = board type
y = number of signaling links
configured on the board
z = number of PCM ports on the
board
See Section 5.4, “Dialogic
®
DSI Network
Interface Board Types” on page 48.
One of the following:
SPCI2S-4-2
SPCI2S-8-2
SPCI4-4-4
SPCI4-8-4
SS7HDP-64-4
BUILDOUT
The buildout type:
0 - Setting for E1 devices.
1 - T1 short haul 0 - 110 ft.
2 - T1 short haul 0 - 110 ft.
3 - T1 short haul 110 - 220 ft.
4 - T1 short haul 220 - 330 ft.
5 - T1 short haul 330 - 440 ft.
6 - T1 short haul 440 - 550 ft.
7 - T1 short haul 550 - 660 ft.
8 - T1 long haul LB0 (-0dB)
9 - T1 long haul LB0 (-7.5dB)
10 - T1 long haul LB0 (-15dB)
11 - T1 long haul LB0 (0dB
TR62411)
0 to 11
Default =
0 for E1
1 for T1
C7LINK
Logical reference for an SS7 signaling
link
1 to 256
C7RT Logical reference of an SS7 route 1 to 4096
CLA
Alarm class number. One of:
0 = Unreported (the alarm is logged,
but it does not trigger an alarm relay
and is not included in SNMP output.
5 = Minor (triggering the MNR alarm
LED and relay)
4 = Major (triggering the MJR alarm
LED and relay)
3 = Critical (triggering the CRT
alarm LED and relay)
0, 3, 4, 5