74
Chapter 6 Command Definitions
Syntax
CNTSP:PCM=;
Prerequisites
None
Attributes
None.
Examples
CNTSP:PCM=3-3;
Output Format
PCM Timeslot Configuration
TS TYPE C7LINK ITS
3-3-22 SIG 6
3-3-24 OTS 4-4-4
3-3-25 RTS 7
3-3-25 STS 8
EXECUTED
6.5.35 CNUPI – Configuration Update Initiate
Synopsis
This command is used to update configuration data, software or a license on the Signaling Gateway. The
operation involves reading files containing either configuration data, software or a license from a Remote
Data Center (if specified) or portable media (CD or USB) and loading it into memory. Optionally, the file may
be read from a subdirectory (DIRECTORY) of the account on the RDC.
A FILE name should be entered on the command line without a suffix. The command automatically reads the
file name with a suffix. The command determines the suffix by use of the DTYPE parameter. For example, the
file CFG.CF3 for a DTYPE of CONFIG would be entered as CFG.
The filename suffix for DTYPE=CONFIG is .CF3.
The filename suffix for DTYPE=SOFTWARE is .tgz.
The filename suffix for DTYPE=LICENSE is .lic.
If not specified, the default filename for a DTYPE=CONFIG is “SDC”.
If not specified, the default filename for a DTYPE=SOFTWARE is “sgw”.
If not specified, the default filename for a DTYPE=LICENSE is “sgw”.
Note: During execution of this command, there system may not respond for up to 3 minutes while the
command is being executed.
Syntax
CNUPI:DTYPE=,RDC=,[DIRECTORY=,][FILE=,];
Prerequisites
• If the RDC is specified, it should be initiated and not blocked.
Attributes
CONFIG
Examples
CNUPI:RDC=1,DTYPE=CONFIG,DIRECTORY=AUTH,FILE=CFG;
Comentários a estes Manuais