6.6 SS7 Signaling Commands
The SS7 signaling commands include:
C7LSI - CCS SS7 Link Set Initiate
C7LSC - CCS SS7 Link Set Change
C7LSE - CCS SS7 Link Set End
C7LSP - CCS SS7 Link Set Print
C7RTI - CCS SS7 Route Initiate
C7RTC - CCS SS7 Route Change
C7RTE - CCS SS7 Route End
C7RTP - CCS SS7 Route Print
C7SLI - CCS SS7 Signaling Link Initiate
C7SLC - CCS SS7 Signaling Link Change
C7SLE - CCS SS7 Signaling Link End
C7SLP - CCS SS7 Signaling Link Print
6.6.1 C7LSI – CCS SS7 Link Set Initiate
Synopsis
This command is used to initiate the SS7 link set (LS) between the point code of the unit, the Originating
Point Code (OPC), and an adjacent point code, the Destination Point Code (DPC). The user should specify the
maximum number of links in the link set (LSSIZE), the SS7 Signaling mode (SS7MD), which identifies the
point code size and mode of operation, and the Network Context (NC) the link set exists within.
See Section 7.2, “Signaling Configuration” on page 137 for a more detailed description of the SS7 Signaling
configuration.
This command is used to initiate the SS7 link set. Note that the DPC (Destination Point Code) is the adjacent
Point Code for the link set.
Syntax
C7LSI:LS=,OPC=,DPC=,LSSIZE=,NI=,SS7MD=,NC=,;
Prerequisites
The SS7 link set has not already been initiated.
The SS7MD associated with a NC cannot be different to an SS7MD associated with the same NC
anywhere else in the system.
The NC/DPC combination must be different for all link sets.
If SS7MD indicates 14-bit Point Code, OPC and DPC must be less than or equal to 16383.
If SS7MD indicates 16-bit Point Code, OPC and DPC must be less than or equal to 65535.
Only one OPC can exist within a network context.
Attributes
CONFIG
Examples
C7LSI:LS=1,NC=1,OPC=1,DPC=2,LSSIZE=2,SS7MD=ITU14,NI=0;