Chapter 8 Alarm Fault Code Listing
Critical
(CRT)
63 PSU failure
The system has detected that one or more
power supplies have failed. The system is able
to operate with the loss of a single power
supply but the power supply must be replaced
at the earliest possible opportunity.
SYS PSU ID 3 0
Critical
(CRT)
72 Fan failure
The system has detected a failure of one or
more or its cooling fans leading to an
inadequate cooling supply. The faulty fan(s)
should be replaced immediately.
SYS 0 3 0
Critical
(CRT)
76 CPU warning
The system has detected that one or more of
the CPUs is likely to fail.
SYS 3
Critical
(CRT)
77 CPU failure
The system has detected that one or more of
the CPUs has failed.
SYS 3
Critical
(CRT)
78 Memory failure
The system has detected that one or more of
its memory modules has failed.
SYS 3
Major
(MJR)
1 PCM loss Loss of signal at PCM input port PCM PCM 4 0
Major
(MJR)
2AIS
PCM input port contains the Alarm Indication
Signal (all ones on all timeslots)
PCM PCM 40
Major
(MJR)
3
Frame sync
loss
Loss of frame alignment on PCM port PCM PCM 4 0
Major
(MJR)
4Frame slip
A frame slip occurred on the PCM port. This
alarm event is given for each occurrence of a
frame slip.
PCM PCM 40
Major
(MJR)
5 Remote alarm
PCM port is receiving a Remote Alarm
Indication. This usually indicates that the
remote end is either failing to achieve frame
alignment or that it is experiencing a high bit
error rate on the received signal.
PCM PCM 4 0
Major
(MJR)
6 BER > 1:10^5
The input PCM signal contains a Bit Error Rate
(BER) in excess of 1 in 100,000 as measured
on the frame alignment pattern. This is
usually due to faulty cabling or a faulty PCM
board at the remote end.
PCM PCM 40
Major
(MJR)
7 BER > 1:10^3
The input PCM signal contains a Bit Error Rate
(BER) in excess of 1 in 1000 as measured on
the frame alignment pattern. This is usually
due to faulty cabling or a faulty PCM board at
the remote end.
PCM PCM 4 0
Major
(MJR)
9 C7 link fail
An SS7 signaling link has failed. Usually due
to incorrect configuration (signaling timeslot),
connectivity fault or inactive signaling
terminal at the remote end.
SIG C7LINK 40
Major
(MJR)
15 Fan warning
The system has detected either the failure of
one of the cooling fans or that a fan is likely to
fail. The cooling will remain adequate during
this condition but the fan should be replaced
at the next convenient opportunity.
SYS 0 4 0
Major
(MJR))
17 Alarm Test 2
This event indicates that the user has invoked
the alarm test for alarm class 2 using the
ALTEI command.
SYS 0 4 0
Major
(MJR)
20 Temperature
The internal temperature is outside a preset
threshold indicating either an internal fault or
failure of the cooling arrangements.
Inspection should take place immediately.
SYS CPU ID 4 0
Major
(MJR)
33 Sync failure
None of the PCM ports that have been
configured as possible clock sources contain a
valid PCM signal. Under these conditions the
Signaling Gateway will generate
synchronisation using a local oscillator.
PCM 040
Table 10. Alarm Fault Codes (Continued)
Severity
(LED)
CODE Name Event Description CATEGORY ID Class
DIAG
† The “Class” column provides the initial default setting of the alarm class for each fault code. The alarm class for any particular alarm code
is configurable using the ALCLS command and can be viewed using the ALCLP command. Changing the alarm class for an event type changes
the Severity indicated by the LEDs and/or relays.