Use Case Examples
175
Under Called address rules, configure the following parameters:
Address Condition: Enter the called address condition as shown in the graphic
above. This condition matches all calls to 192.168.212.138, which is the IP address
of the FSX ATA.
Address Result: Enter the called address result as shown in the graphic above,
with the FDQN of the SBA after the @ sign. This address result converts the
matched called addresses to a form accepted by the Lync Server.
Under Calling address rules, configure the following parameters:
Address Condition: Enter the calling address condition as shown in the graphic
above. This condition matches all calls from 192.168.212.138, which is the IP
address of the FXS ATA.
Address Result: Enter the calling address result as shown in the graphic above,
with the FDQN of the SBA after the @ sign. This address result converts the
matched calling addresses to a form accepted by the Lync Server.
Click OK to save the settings and close the window.
14.
Under PSTN Interfaces, configure both Controller 1 and Controller 2 with PSTN-
specific settings. The controller numbers that you configure with PSTN-specific settings
needs to correspond to the line numbers in the Diva Configuration Manager on which
you configured the switch type of your PSTN lines.
To configure PSTN-specific parameters for Controller 1, click Details to the right of the
respective controller, and configure the following parameters: