113
11. Event Logging
Event Logging
A computer with Diva SIPcontrol installed can write the following types of events into the
System Event Log:
Errors
Warnings
Informational Messages
You can view the events in the Windows
®
Event Viewer. To do so, click Programs >
Settings > Control Panel > Administrative Tools. In the Administrative
Tools window, double-click Event Viewer and then Application, where Diva SIPcontrol
stores the events.
Errors
An error is a significant problem, such as loss of data or loss of functionality. For example, if
a service fails to load, an error event will be logged.
See below for possible error events. Variables are enclosed in angle brackets. Parameters
enclosed in square brackets are optional:
Service could not start.
<Reason>
The <Reason> is text that explains why the
service could not start.
Service could not stop.
<Reason>
The <Reason> is text that explains why the
service could not stop.
Updating configuration failed.
<Reason>
The new configuration could not be activated,
probably due to invalid configuration data.
Cannot bind to IP address.
<IP address>:<port>
[<protocol>].
The service cannot be bound to the IP
address.
TLS initialization failed, call
attempt aborted.
The configured TLS settings are invalid, or a
required file is missing.
For calls to SIP only: the call is aborted unless
an alternate destination without TLS
encryption is available.