Chapter 6 Command Definitions
6.10.3 MSPCP – Measurements PCM Print
Synopsis
This command prints traffic measurements for PCMs. The measurements are cumulative between system
startup and the next time the measurements are reset.
The fields have the following meanings:
PCM - PCM on a board
FMSLIP - Frame Slip count
OUTSYN - Out-sync transitions
ERRSEC - Errored Seconds count
SEVSEC - Severely Errored seconds count
PERIOD - Time since measurements on the route were last reset. Specified in hours, minutes and
seconds
Syntax
MSC7P:[C7LINK=,][RESET=,];
Prerequisites
If specified, the PCM must be initiated and on an unblocked board.
Attributes
None
Examples
MSPCP:PCM=5-1;
MSPCP;
Output Format
PCM Traffic Measurements
PCM FMSLIP OUTSYN ERRSEC SEVSEC PERIOD
3-3 57 60 23 1 23:00:00
3-4 12 35 33 4 01:00:00
4-4 53 55 4 0 01:00:00