6.11.5 RDPDI – Remote Data Centre Periodic Data Initiate
Synopsis
This command attaches an SS7 link (C7LINK), SIGTRAN link (SNLINK) or PCM (PCM) to a periodic report.
Syntax
RDPDI:REPORT=,[C7LINK=|SNLINK=|PCM=];
Prerequisites
The report has already been initiated.
The specified SS7 link has already been initiated.
SS7 links can only be specified for MSC7 reports.
An association between the report and the SS7 link has not already been initiated.
Attributes
CONFIG
Examples
RDPDI:REPORT=1,C7LINK=1&&8;
6.11.6 RDPDE – Remote Data Centre Periodic Data End
Synopsis
This command ends the attachment between an outgoing route and a report.
Syntax
RDPDE:REPORT=,[C7LINK= | SNLINK=| PCM=];
Prerequisites
The report has already been initiated.
An association between the report and the SS7 link has already been initiated.
Attributes
CONFIG
Examples
RDPDE:REPORT=1,C7LINK=1;