SS7G2x Signaling Server SGW Mode User Manual Issue 4
6.11.2 RDCRC – Remote Data Centre Continuous Record Change
Synopsis
This command changes the parameters for a continuous record collection for which collected data is
transferred via Ethernet to a Remote Data Centre (RDC).
The period is the maximum amount of time allowed before the transfer of a block of continuous records must
be performed.
The label is used as the directory name on the RDC that the files are written to.
Syntax
RDCRC:RECORD=,[PERIOD=,][MINREC=,][RDC1=,][RDC2=,][LABEL=];
Prerequisites
The record must already be initiated.
If specified, RDC1 must already be initiated.
If specified, RDC2 must already be initiated
If specified, RDC2 must not equal RDC1.
Limitations
Before transfer to a RDC can take place, the directory (represented by the label) must exist on the
remote site.
PERIOD must be in the range 30 seconds to 30 minutes.
Attributes
CONFIG
Examples
RDCRC:RECORD=1,PERIOD=00:05:00,MINREC=100,
RDC1=1,LABEL=ALARM;